page_banner

products

EVI -25℃ 18KW Air Source High Temp Heat Pump Water Heater BLH36-038S

Short Description:

1. Heat pump with 60hz three phase, fit for hotel, hospital and commercial project.
2. Offer high temp hot water any time even bad weather like rainy, cloudy and etc.
3. Easy outdoor installation, able to combine with tank or solar.
4. Powerful controller —With temp difference of 0.1 deg c, much more precisely.
5. Timer function—Ensure you could ask heat pump to heating the water in advance before you need it. And also can make heat pump to work at 9am to 11am which with higher air temp in the daytime, to get the better heating performance and reduce the heating time.


Product Detail

PARAMETERS

Product Tags

 ● Green and Environmental Protection

By using air energy and electric energy, there is no harmful gas being discharged during the work of heat pump. R134A refrigerant guarantees fluoride-free emission.

r410a

 ● High outlet water temp.

A regular heat pump therefore takes longer than a boiler to heat your home, meaning you need larger radiators to ensure it won’t take forever, and insulation to stop heat from escaping during this process.

High temperature heat pumps can output max 80C high water temp , and it can operate at the same heating level as gas boilers, meaning you can replace one with the other without having to get new radiators or insulation.

80c

 ● Durable & Stable Running at -25℃ Ambient Temp

Thanks to the The Enhanced Vapor Injection (EVI) technology from Copeland compressor and other brand components of the heat pump, the unit could be stable running at -25℃ Ambient Temperature guarantee high quality and a long lifespan.

And all of our screws and clips (both external and internal) are stainless steel. The cabinet we are using is made of  galvanized steel, making them more rust resistant and durable. 

cop

 ● Smart Defrost Technology

Intelligent defrost technology to reduce the defrosting times and thus extend the unit heating time. Rapid defrost to shorten defrost time can help to recover supply water temperature quickly, improve the unit heating efficiency and maintain comfort.

deforest

 ● Wide Application

High temperature heat pumps can be very efficient for hot water production and have been adopted in commercial settings for hotels and restaurants where there is high hot water demand. The unit can be used in industrial applications such as electrioplating factory, food disinfection or drying. laundry etc. And it can also be used in hotels for hot water supply with a smaller tank.

connect

 ● Multiple Protections

For example, if water flow is not enough in the system, the system will show high pressure protection and stop the heat pump automatically to protect the compressor from being damaged. Also, there is high current protection: if the power supply is not stable, the heat pump will show the high current error to stop the heat pump and avoid compressor damage

protect

 ● Quality-guranteed Components

Use international famous brand components equipping

Quality-guaranteed Components

 Model

BLH36-038S

Rated heating capacity

kw

18

BTU/H

61200

COP

w/w

4

 Heating power input

kw

4.5

Fan power input

w

360

Max outlet water temp

85

Applicable ambient temp

° C

-25~43

Water flow volume

M3/H

3.1

Water pressure drop

kPa

60

Compressor

Copeland Scroll

Fan direction

Horizontal

Fan speed

RPM

750

Noise level

dB(A)

56

Water connections

Inch

1"

 Net dimension       (LxWxH)

mm

1115*470*1250

 Packing dimension (LxWxH)

mm

1220*490*1400

Net weight

KG

154

Gross weight

KG

174

Power supply

V/Ph/Hz

380/3/60

FAQ

1.Where can heat pump units be used?
Heat pump units are widely used, including various types of commercial machines specially designed for hotels, schools, hospitals, saunas, beauty salons, swimming pools, laundry rooms, etc.; there are also various types of household machines specially designed for families.  At the same time, it can also provide free air cooling, which can realize the whole year heating.

2.If there is any problems of the heat pump in the future, how to fix it?
We do have unique bar code number for each unit. In case heat pump has any problems, you can describe more details to us together with the bar code number. Then we can trace the record and our technician colleagues will discuss how to solve the problem and update to  you.

EVI Low-ambient Heat Pump
2-3

  • Previous:
  • Next:

  •  Model BLH36-038S
    Rated heating capacity kw 18
    BTU/H 61200
    COP w/w 4
     Heating power input kw 4.5
    Fan power input w 360
    Max outlet water temp 85
    Applicable ambient temp ° C -25~43
    Water flow volume M3/H 3.1
    Water pressure drop kPa 60
    Compressor Copeland Scroll
    Fan direction Horizontal
    Fan speed RPM 750
    Noise level dB(A) 56
    Water connections Inch 1″
     Net dimension       (LxWxH) mm 1115*470*1250
     Packing dimension (LxWxH) mm 1220*490*1400
    Net weight KG 154
    Gross weight KG 174
    Power supply V/Ph/Hz 380/3/60
  • Write your message here and send it to us