Manufacturer for Dc Invert Heat Pump - R32 R290 EVI DC Inverter Multifunction Air-to-water Heat Pump BLB1I-100S 130S BLB3I-130S 180S – O.S.B.
Manufacturer for Dc Invert Heat Pump - R32 R290 EVI DC Inverter Multifunction Air-to-water Heat Pump BLB1I-100S 130S BLB3I-130S 180S – O.S.B. Detail:
Model | BB11-100s | BB11-130S | BB11-180S | BB31-180S | Measuring conditions | ||
Refrigerant | R32 | R32 | R32 | R32 | |||
Suitable room size | m² | 170 | 240 | 320 | 320 | ||
Water production | L/h | 180 | 250 | 340 | 340 | ||
Power supply | VPh/Hz | 220~240/1/50-60 | 220~240/1/50-60 | 220~240/1/50-60 | 380/3/50-60 | ||
Air heating | Rated heating capacity | kw/Btu | 8.5/28990 | 12/40932 | 16/54576 | 16/54576 | Dry bulb:7℃ Wet bulb:6℃ Water inlet:30℃ Water outlet:35℃ |
Heating input power | kw | 1.89 | 2.45 | 3.56 | 3.56 | ||
Running current | A | 8.6 | 11.3 | 16.2 | 5.5*3 | ||
cOP | w/w | 4.5 | 4.9 | 4.5 | 4.5 | ||
Air heating | Rated heating capacity | kw/Btu | 8.5/28990 | 12/ 40932 | 16/54576 | 16/54576 | Dry bulb:7℃ Wet bulb:6℃ Water inlet:40℃ Water outlet:45℃ |
Heating input power | kw | 2.43 | 3.3 | 4.6 | 4.6 | ||
Running current | A | 11 | 15.2 | 20.1 | 7.1*3 | ||
cOP | w/w | 3.5 | 3.7 | 3.5 | 3.5 | ||
Domestichot water | Rated heating capacity | kw/Btu | 8.5/28990 | 12/40932 | 16/54576 | 16/54576 | Dry bulb:7℃ Wet bulb:6℃ Water inlet:47℃ Water outlet:55℃ |
Heating input power | kw | 3 | 4 | 5.7 | 5.7 | ||
Running current | A | 13.7 | 18.2 | 26 | 8.7*3 | ||
cOP | w/w | 2.8 | 3 | 2.8 | 2.8 | ||
Air cooling | Rated cooling capacity | kw/Btu | 8/27280 | 12/40932 | 14.8/50482.8 | 14.8/50482.8 | Dry bulb:35℃ Wet bulb:24℃ Water inlet:23℃ Water outlet:18℃ |
Cooling input power | kw | 2.43 | 3.33 | 4.35 | 4.35 | ||
Running current | A | 11.1 | 15.2 | 20 | 6.7*3 | ||
EER | w/w | 3.3 | 3.6 | 3.4 | 3.4 | ||
Air cooling | Rated cooling capacity | kw/ Btu | 7.4/25240 | 11.5/39226.5 | 14/47754 | 14/47754 | Dry bulb:35℃ Wet bulb:24℃ Water inlet:12℃ Water outlet:7℃ |
Cooling input power | kw | 3.1 | 4.26 | 5.6 | 5.6 | ||
Running current | A | 14.1 | 19.6 | 25.8 | 8.6*3 | ||
EER | w/w | 2.4 | 2.7 | 2.5 | 2.5 | ||
Max outlet water temp | ℃ | 55 | 55 | 55 | 55 | ||
Applicable ambient temp | ℃ | -15~43 | -15~43 | -15~43 | -15~43 | ||
Noise | dB(A) | 60 | 65 | 65 | 65 | ||
Water connections | Inch | 1″ | 1″ | 1″ | 1″ | ||
Compressor type | Rotary | Rotary | Rotary | Rotary | |||
Fan qty | PC | 1 | 2 | 2 | 2 | ||
Net dimensions | mm | 1115x470x935 | 1415x470x1250 | 1415x470x1250 | 1415x470x1250 | ||
Packing dimensions | mm | 1200x480x1090 | 1520x480x1380 | 1520x480x1380 | 1520x480x1380 | ||
Erp energy efficiency | 35℃A+++/55℃A++ |
Model | BLB1I-100S | BLB1I-130S | BLB3I-130S | BLB3I-180S | ||
Refrigerant | R32 | R32 | R32 | R32 | ||
Suitable room size | ㎡ | 54-220 | 90-320 | 90-320 | 140-420 | |
Water production | L/h | 195 | 280 | 280 | 370 | |
Power supply | V/Ph/Hz | 220-240/1/50-60 | 220-240/1/50-60 | 380/3/50-60 | 380-3/50-60 | |
Air heating/ DHW | Rated heating capacity | kw | 2.7-11 | 4.5-16 | 4.5-16 | 7-21 |
BTU | 9200-37520 | 15300-54500 | 15300-54500 | 23800-71630 | ||
Heating input power | kw | 1.04-3.44 | 1.67-4.85 | 2.6*3-7.5*3 | 3.9*3-9.5*3 | |
Running current | A | 4.8-15.8 | 7.7-22.3 | 7.7-22.3 | 11.5-28.4 | |
COP | w/w | 2.6-3.2 | 2.7-3.3 | 2.7-3.3 | 2.8-3.4 | |
Air cooling | Rated cooling capacity | kw | 2.5-7.5 | 3.8-11 | 3.8-11 | 4.8-14.5 |
BTU | 8520-25580 | 12960-37520 | 12960-37520 | 16370-49450 | ||
Cooling input power | kw | 1.14-4.42 | 1.81-6.88 | 1.81-6.88 | 2.18-8.53 | |
Running current | A | 5.3-20.1 | 8.3-31.6 | 2.9*3-10.6*3 | 3.5*3-13.1*3 | |
EER | w/w | 1.7-2.2 | 1.6-2.1 | 1.6-2.1 | 1.7-2.2 | |
Max outlet water temp | ℃ | 55 | 55 | 55 | 55 | |
Applicable ambient temp | ℃ | -25~43 | -25~43 | -25~43 | -25~43 | |
Noise | dB(A) | 55 | 60 | 60 | 60 | |
Water connections | Inch | 1″ | 1″ | 1″ | 1″ | |
Compressor type | Rotary | Rotary | Rotary | Rotary | ||
Net dimensions | mm | 1115*470*935 | 1415*470*1250 | 1415*470*1250 | 1415*470*1250 | |
Packaging dimensions | mm | 1215*470*935 | 1520*490*1400 | 1520*490*1400 | 1520*490*1400 | |
Electric heater | kw | 3 | 3 | 3 | 3 | |
Fan qty | PC | 1 | 2 | 2 | 2 | |
Erp energy rating | 35℃ A+++/55℃ A++ | |||||
Measuring conditions: | Air heating: Dry bulb:7℃, Wet bulb:6℃. Water outlet:45℃. Air cooling: Dry bulb:35℃,Wet bulb:24℃. Water inlet:12℃. |
Model | BLB1I-070S | BLB1I-100S | BLB1I-130S | BLB1I-180S | ||
Refrigerant | R290 | R290 | R290 | R290 | ||
Suitable room size | ㎡ | 62-170 | 84-240 | 108-300 | 160-440 | |
Power supply | V/Ph/Hz | 220~240/1/50-60 | 220~240/1/50-60 | 220~240/1/50-60 | 220~240/1/50-60 | |
Air heating/ DHW | Rated heating capacity | kw | 3.1-8.5 | 4.2-12 | 5.4-15 | 8-22 |
BTU | 10570-29000 | 14320-40930 | 18420-51160 | 27280-75000 | ||
Heating input power | kw | 0.66-2.02 | 0.9-2.86 | 1.2-3.85 | 2-6.5 | |
Running current | A | 2.9-9.2 | 4.2-13.2 | 5.5-17.7 | 9.1-29.7 | |
COP | w/w | 4.2-4.7 | 4.2-4.7 | 3.9-4.5 | 3.4-4 | |
Air cooling | Rated cooling capacity | kw | 1.2-5.7 | 3-8.4 | 3.6-10.5 | 4.2-15 |
BTU | 4090-19400 | 10230-28650 | 12280-35800 | 14300-51160 | ||
Cooling input power | kw | 0.65-2.4 | 1.25-4 | 1.12-4.5 | 1.8-7.3 | |
Running current | A | 2.9-10.5 | 5.8-18.5 | 4.9-19.6 | 7.9-32.2 | |
EER | w/w | 1.8-2.3 | 2.1-2.4 | 2.3-3.2 | 2.05-2.3 | |
Max outlet water temp | ℃ | 60-75 | 60-75 | 60-75 | 60-75 | |
Applicable ambient temp | ℃ | -25-43 | -25-43 | -25-43 | -25-43 | |
Noise | d B(A) | 50 | 55 | 60 | 60 | |
Water connectionns (air heating/cooling) |
Inch | 1″ | 1″ | 1″ | 1″ | |
Compressor qty | PC | 1 | 1 | 1 | 1 | |
Compressor type | Rotary | Rotary | Rotary | Rotary | ||
Fan qty | PC | 1 | 1 | 2 | 2 | |
Net dimension LxWxH | MM | 1115*470*685 | 1115*470*935 | 1115*470*1250 | 1415*470*1250 | |
Packing dimension LxWxH | MM | 1220*480*710 | 1200*480*1090 | 1200*480*1380 | 1520*480*1380 | |
Auxiliary electrical heating | KW | 3 | 3 | 3 | 3 | |
ErP Energy efficiency grade | 35℃A+++/55℃A++ | |||||
Measuring conditions: | Air heating: Dry bulb:7℃, Wet bulb:6℃. Water outlet:45℃. Air cooling: Dry bulb:35℃,Wet bulb:24℃. Water inlet:12℃. |
Product detail pictures:
Related Product Guide:
Our mission is usually to turn into an innovative provider of high-tech digital and communication devices by furnishing benefit added design and style, world-class manufacturing, and service capabilities for Manufacturer for Dc Invert Heat Pump - R32 R290 EVI DC Inverter Multifunction Air-to-water Heat Pump BLB1I-100S 130S BLB3I-130S 180S – O.S.B. , The product will supply to all over the world, such as: South Korea, Norway, Zimbabwe, Our expert engineering team will generally be prepared to serve you for consultation and feedback. We're able to also give you with free of charge samples to meet your requirements. Best efforts will likely be produced to provide you the best service and merchandise. When you are keen on our business and items, make sure you speak to us by sending us emails or call us quickly. In an effort to know our merchandise and company extra, you may come to our factory to view it. We'll generally welcome guests from all over the world to our business to create business relations with us. Be sure to feel cost-free to speak to us for small business and we believe we are going to share the best trading experience with all our merchants.
By Freda from Roman - 2017.07.28 15:46
Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
By Dominic from Turkey - 2017.08.18 11:04
Write your message here and send it to us